preventative maintenance
Have condenser coils, evaporator and fans cleaned by qualied personal twice a year or as necessary
troUBleShooting
troubleshootIng ChArt
Problem It might be caused by Course of Action
No power to unit.
Faulty outlet. Have outlet replaced by qualied personal.
Circuit breaker tripped. Reset the circuit breaker.
Compressor does not run.
Compressor in “delay” cycle. Wait two minutes for compressor to run.
Faulty controller.
Have unit serviced by qualied personal.Faulty compressor.
Faulty compressor starter or capacitor.
Compressor runs temperature inside too warm.
Ambient temperature too high. Ensure lower ambient temperature.
Excessive ice/frost build up on evaporator. Use manual defrost function.
Faulty controller.
Have unit serviced by qualied personal.Dirty or faulty condenser fan.
Dirty or faulty evaporator fan.
WARNING
Electrical Shock Hazard.
Keep water and other liquids from entering the
inside of the equipment. Liquid inside the equipment
could cause an electrical shock.
Do not spray water or cleaning products. Liquid could contact the
electrical components and cause a short circuit or an electrical
shock. Do not use equipment if power cord is damaged or has been
modied
NOTE:
Do not immerse the cord, plug or equipment in water
or any other liquid. Do not use a hose to clean this
equipment.
1. Unplug the equipment.
2. Use a damp cloth or sponge dipped in soapy water to clean the
equipment; rinse and dry thoroughly.
3. A high quality non-toxic glass cleaner may be used to clean the glass
components of the unit.
4. Periodical remove the rear panel and clean the coil ns with a stiff
brush.
cleaning
To maintain the appearance and increase the service life, clean your equipment
daily.
NOTE:
Do not use cleaning products containing aggressive
chemicals, acids, or that contain chlorine.